Data
Observed data from 2003 VTEM and 2005 RESOLVE surveys are shown below in Fig. 546 with down-sampled data locations shown as black dots. The images show imaginary z-component H-field measurements from the lowest frequency (385 Hz) and highest frequency (115,000 Hz) as well as z-component dB/dt data from the earliest (150 us) and latest time channel (3180 us). Note that time-domain measurements below \(5 \times 10^{-12}\) V/Am \(\! ^2\) are removed for noise concern purposes. The data plots show that both surveys do an excellent job detecting the three main conductive units, however the RESOLVE survey does a better job at detecting near surface features such as clay layers in shallow lakes, which are more conductive than the background. The 2005 RESOLVE system utilizes a much higher frequency compared to the equivalent earliest time channel in the 2003 VTEM system and as a result, the frequency domain data has a higher sensitivity to near-surface objects compared to the time-domain measurements.